Installation of air conditioning unit




















These oils cannot be mixed without damaging the new air conditioning system. Sometimes the line set is concealed by a ceiling or in a wall, or it is buried underground or in concrete. Sometimes providing access is not an option or possible. In these cases, you have the option of finding a new location to run a new line set or reusing the existing line set remains. If the existing line set must be reused, it must be flushed and cleaned properly, then pressure tested.

It is never recommended to keep an existing line set if it can be replaced. There are two options when installing a new evaporator coil for any new air conditioner system: cased and uncased.

The preferred option is a cased coil, because it comes in an insulated cabinet with removable panels on the front that allow access to the coil inside. The cased coil is also designed to sit on top of the furnace without any modifications, which makes repairs and modifications easy. In most cases, it will be painted to match the color of the furnace.

The biggest benefit of using a cased coil is that it comes pre-cased by the manufacturer. This makes failure from an improper installation highly unlikely, regardless of the skill level of the installer.

The final step at that point is to connect and seal it to the existing sheet metal plenum. An uncased coil is the coil without an insulated cabinet. They have more installation requirements and longer preparation time. They are available in the same variations as the cased coil. Uncased coils are typically more difficult to install. However, an uncased coil will provide the same comfort and be just as efficient as a cased coil when installed properly.

Before the coil can be built into the existing sheet metal supply plenum, there is specific preparation required. These requirements are specified by the manufacturer. The drain pan on the coil is plastic, so rails need to be fabricated by the installer to make sure the coil is sitting the proper distance above the furnace heat exchanger. This keeps the drain pan from melting. If the drain pan melts into the furnace, it could permanently damage the furnace or cause a fire. Once the rails are built and installed, the coil can be installed into the supply plenum.

If the plenum is larger than the coil, a sheet metal pan must be built with an opening provided below the coil. This opening needs to mirror the bottom opening of the coil for proper airflow from the furnace going through the coil.

If the opening is not big enough, or too much air goes around the coil instead of through it, the coil will freeze into a block of ice. This can damage the coil and cause a refrigerant leak by cracking the tubing carrying the refrigerant. Once those are installed, the final step is building the front of the plenum. It is possible to build an access panel door into the plenum to cover the coil. This is not required by any code or manufacture specification, so it would be up to the installer.

In all scenarios, the cover must have holes provided for the refrigerant lines, and then also for the condensation lines to be connected. The type of coil chosen is mostly based on the details of the installation. Regardless, if the coil is installed per code and manufacture specifications to the existing duct system, can drain properly, and is sealed from air leaks, you will enjoy the same level of comfort.

There is no difference in warranty or life expectancy between either type of coil. The new refrigerant line set is a combination of two individual copper lines. One line is always bigger than the other and is insulated. The bigger line is called the suction line, and the little one is called the liquid line.

They come packaged together, rolled in a coil. It is available in multiple selections of lengths, from feet. You will rarely need more than 50 feet in a residential home. The key is installing the line with as few bends and turns as possible. When these bends are necessary, the soft copper can be bent by hand or a tubing bender. Plastic or copper strapping is common. Galvanic corrosion also called bimetallic corrosion is the breakdown of metal when two dissimilar metals come into contact.

This does take some time to occur. Nevertheless, if allowed to occur, it could eventually reduce the integrity of the copper refrigerant line over time until it causes a leak. After the hangers are installed, the line set can now be put in place. Typically, an installer will start with the suction line and roll out one end a few feet, leaving the rest of the roll in a coil. They then push the unrolled section through a hole drilled through the band board of the house to the outside, near the air conditioner.

Enough of the line is pushed out to reach the service valve of the air conditioner. Eventually, the installer will connect this line to the air conditioner itself. The hole size will be between After the line is outside by the air conditioner, the line is secured by hangers near the hole and then another hanger back a couple of feet.

The line is then carefully uncoiled and formed along the floor joists up against the trunk line ductwork or a beam, as straight as possible until long radius turns or bends are needed. Along the way, it gets put into the hangers that have been installed previously, securing it in place.

The line set will run from the air conditioner outside to the new indoor evaporator coil on top of the furnace. After the suction line has been installed and secured, the smaller, liquid line is run along the suction line, secured in the same hangers. A line set should be new, installed as one piece, free from any sharp bends or kinks, and secured with an appropriate hanging system. There will also be a small, low-voltage control wire that runs from the furnace along the line set to the air conditioner outside.

The small existing wire coming from the thermostat to the furnace sends a low voltage signal to the air conditioner to turn on and off when a call for cooling is needed or has been satisfied. Removing the new air conditioner and setting it on the pad is step one. After uncrating the unit, a good installer will inspect for any damage. Sometimes panels or coils will get damaged in transit.

Any damage should be reported to you immediately. However, you always have the right as a customer to not accept the damaged unit and ask for another one. The line set that was installed in the previous step is then formed and fitted to the appropriate service valve on the new air conditioner.

The service valve is a connection point for the line set, and also isolates the refrigerant contained inside the unit. Service valves also allow for the outdoor condenser portion of the air conditioner to be isolated from the indoor coil and line set for future service or repair needs when needed.

Isolating the refrigerant keeps you from having to replace it with all new refrigerant in case of a repair in the future. After the line set is fitted to the service valves, they must be brazed in. Brazing, a form of welding, is a process using two gases oxygen and acetylene and a filler rod made of an alloy metal and silver to join the copper line set and service valves.

The valves are heated to a minimum of degrees Fahrenheit or until the filler rod will flow to weld the connection. If this process is completed properly, the copper line set, the filler rod, and the service valve are all melted together for a tight, leak-free connection. Filter driers are a key component in the refrigerant system.

They serve two main functions. The most important function of a filter drier is to absorb moisture. The second is to provide physical filtration. When installing a new air conditioner condenser, you must always install a liquid line filter drier into the refrigeration system.

Most new air conditioner condensers come with a liquid line filter drier for you to install. Manufacturers recommend the filter drier be installed close to the expansion valve TXV at the indoor coil, as often as possible. This keeps the TXV protected and keeps the filter drier from being exposed to weather where it could rust. There is also an arrow for flow direction. This arrow must always be in the direction that is going into the indoor coil. Moisture enters the system in different ways.

If a system is not evacuated properly, moisture will exist in it. Moisture can also come from leaks or motor windings. The water can cause corrosion and create failure in metallic parts. Water or moisture can also react with the oil in the refrigerant system. This is called hydrolysis, which forms acids in the system. Acids, moisture, or any other contamination in the lines will be extremely dangerous to the integrity of your new air conditioning system. All good HVAC companies have strict processes in place for their install teams to prevent failure as much as possible.

Any time a refrigerant line is open to the atmosphere, it is vital to install a new filter drier. This is true of installations as well as service repairs. This brazing process is the same for connection to the indoor evaporator coil. This, again, involves open flames and should only be performed by a trained professional. The gases used in the process are explosive. There is an open flame outside and inside the home. It can be dangerous to the installer, the homeowner, and the home, causing permanent damage without proper training.

Following manufacturer and safety guidelines is key. Preparing the line set for refrigerant in this way is the most important step in ensuring the safety and efficiency of your air conditioner. Sadly, this process is unknown or not followed to most install teams. Not all companies are equal in training or processes, and many contractors lack the proper equipment. A good HVAC company will have all the tools and processes needed to install the air conditioner professionally and thoroughly. After the line set is fitted properly into the service valves and indoor coil, heat protection needs to be applied.

Heat protection can be a heat-absorbing paste, wet towels, or rags. Anything that would keep the heat spreading into either of the coils is acceptable. If the valves are overheated and the O-rings are damaged, the refrigerant will leak past the valve into the line set, losing the factory charge. From the factory, the air conditioner condenser is prepared, cleaned, and the refrigerant is added. Next attach the foam piece to the window part that moves.

Once the foam is in place insert the actual plastic window piece and close the window tight. Pull out any expansion pieces so that there is a nice tight seal between your room and the outside world. Step 3: Secure The Seal. Step 4: Final Setups. Window air conditioners are another popular installation choice because they're both easy to put in and convenient to operate. They are the cooling method of choice in apartments and even bedrooms for those who prefer a rather chilly sleep.

Installing a Window Air Conditioner. First set the bottom of the window air conditioner into the bottom sill of the window. Once the air conditioner is marginally secured in the window, locks should be placed so the window pane cannot open.

Create a Seal. Installing Split Air Conditioner. Installing a split air conditioner is a more advanced process. To better understand the basics of the install it's easier to break them down in three areas: Outside Condenser - This large receptacle resembles what one might be accustomed to seeing outside of a home with a central air conditioning unit.

Since the cooling capacity is much smaller the single air condenser isn't near the size as a central air unit. The condenser is placed outside so that the noise of it running doesn't bother people inside and so that there's more ventilation for the hard-working coils.

The condenser is placed on a slab near the home. Inside Vent - The inside vent is the brains of the operation where the temperature is controlled and the cool air is delivered.

The vent is the messenger so to speak, the condenser does all the hard work outside and the vent brings the good news inside. The Connectors - Of course lines are needed to connect the two devices with copper wire delivering refrigerant, wires carrying electricity, and tubes dispensing the water that is formed in the cooling process outside.

Installing a Central Air Conditioner. The most detailed process of the central air conditioner setup is the running of duct work to all the different rooms in the house. More often than not the best time to install a central air conditioner is when a house is just being built or when an expansive remodel is being done as that allows the best access to install the ducts.

In a nutshell, installing a central air conditioner involves three main setups: Thermostat - The thermostat controls the first phase of a central air conditioner, the temperature control. This is the device that will tell all the other components to kick into action when it detects that temperatures are getting too high.

C ooling - The cooling process involves the compressor condensing refrigerant, the condenser coils sending the liquid to the evaporator coils where it is turned into a gas and the compressor converting the gas back into a liquid to complete the cycle.

This passage of refrigerant from a liquid to a gas back to a liquid is the process in which the air gets cooled. Depend on the air conditioning experts at Comfort-Air Engineering, Inc for all your air conditioning and replacement needs.

Contact us at today. Are you worried about overspending on your AC needs? Make sure to visit our coupons page so that you can start saving before you call.